![](images/productsandservices_label.jpg)
BioLED > 12W Flat Light |
![](bioled/12wFlatLight.jpg)
|
▶ Sensor-type Dimming LED Flat Light (12W~4W)
• differentiated from normal on/off light sensors
• no need for a separate controller as controlling system comes with the CPU
• reciprocal interlocking operation between LEDs using LAN cables
▶ Power Saving Mode – 4W or OFF
▶ Sensor Algorithm
• sensor detects movement => full brightness at 12W for 2 minutes
=> Light dims over 2 minutes => Maintains a minimum brightness at 4W
▶ Application
• underground parking lots
• interior lights
• hallways, stairways, etc.
|
Type |
Unit |
BL-12-AA-12E |
Symbol |
Power Consumption |
W |
12 |
Max. |
Input Voltage |
V |
220 |
- |
Act Temp |
℃ |
-20~60 |
- |
Dimension |
mm |
768 x 139 x 46 |
Size |
Weight |
kg |
1.4 |
- |
|
|
BioLED > 23W Flat Light |
![](bioled/23wFlatLight.jpg)
|
▶ Sensor-type Dimming LED Flat Light (23W~4W)
• differentiated from normal on/off light sensors
• no need for a separate controller as controlling system comes with the CPU
• reciprocal interlocking operation between LEDs using LAN cables
▶ Power Saving Mode – 4W or OFF
▶ Sensor Algorithm
• sensor detects movement => full brightness at 23W for 2 minutes
=> Light dims over 2 minutes => Maintains a minimum brightness at 4W
▶ Application
• underground parking lots
• interior lights
• hallways, stairways, etc.
|
Type |
Unit |
BL-23-AA-23E |
Symbol |
Power Consumption |
W |
23 |
Max. |
Input Voltage |
V |
220 |
- |
Act Temp |
℃ |
-20~60 |
- |
Dimension |
mm |
1066 x 139 x 46 |
Size |
Weight |
kg |
2.5 |
- |
|
|
BioLED > 40W Flat Light |
![](bioled/40wFlatLight.jpg)
|
▶ Sensor-type Dimming LED Flat Light (40W~4W)
• differentiated from normal on/off light sensors
• no need for a separate controller as controlling system comes with the CPU
• reciprocal interlocking operation between LEDs using LAN cables
▶ Power Saving Mode – 4W
▶ Sensor Algorithm
• sensor detects movement => full brightness at 40W for 2 minutes
=> Light dims over 2 minutes => Maintains a minimum brightness at 4W
▶ Application
• underground parking lots
• interior lights
• hallways, stairways, etc.
|
Type |
Unit |
BL-40-PS-AA |
Symbol |
Power Consumption |
W |
40 |
Max. |
Color Rendering |
|
75 |
- |
Input Voltage |
V |
220 |
- |
Color Temperature |
K |
6,000~7,100 |
Kelvin |
Lumen |
Lm |
2,600 |
Lumen |
Act Temp |
℃ |
-20~60 |
- |
Dimension |
mm |
1250 x 183 x 46 |
Size |
Illumination |
Lx |
680 |
- |
|
|
BioLED > 40W Flat Panel Light |
![](bioled/40wFlatPanelLight.jpg)
|
▶ Sensor-type Dimming LED Flat Light (40W~4W)
• differentiated from normal on/off light sensors
• no need for a separate controller as controlling system comes with the CPU
• reciprocal interlocking operation between LEDs using LAN cables
▶ Power Saving Mode – 4W
▶ Sensor Algorithm
• sensor detects movement => full brightness at 40W for 2 minutes
=> Light dims over 2 minutes => Maintains a minimum brightness at 4W
▶ Application
• interior lights
|
Type |
Unit |
BLS-12AE |
Symbol |
Power Consumption |
W |
40 |
Max. |
Input Voltage |
V |
220 |
- |
Act Temp |
℃ |
-20~60 |
- |
Dimension |
mm |
600 x 600 x 75 |
Size |
Weight |
kg |
4.5 |
- |
|
|
BioLED > Circular Sensor Light |
![](bioled/bioled_circular.jpg) |
▶ Sensor-type Dimming LED Flat Light (12W~4W)
• differentiated from normal on/off light sensors
• no need for a separate controller as controlling system comes with the CPU
• reciprocal interlocking operation between LEDs using LAN cables
▶ Power Saving Mode – 3W or OFF
▶ Sensor only works at nigh by using the function which realizes day and night
▶ Sensor Algorithm
• sensor detects movement => full brightness at 12W for 2 minutes
=> Light dims over 2 minutes => Maintains a minimum brightness at 3W
▶ Application
• hallways, stairways, etc.
|
Type |
Unit |
BLS-12AE |
Symbol |
Power Consumption |
W |
12 |
Max. |
Input Voltage |
V |
220 |
- |
Act Temp |
℃ |
-20~60 |
- |
Dimension |
mm |
235 x 235 x 110 |
Size |
Weight |
kg |
1 |
- |
|
|
|
|